2GPE COMPACT E-SPD
Domestic pressure GPE with inverter
Booster sets with two horizontal cast iron multi-stage pumps Two COMPACT series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. 2GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 40°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Shaft in AISI 416
- Glass fibre reinforced technopolymer impeller
- Mechanical seal in Ceramic/Carbon/NBR
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz, Three-phase voltage 230/400V ±10% 50Hz
2GP -3GP INDUSTRIAL (VERSIONS ON REQUEST)
Industrial pressure GP with control panel
TYPICAL APPLICATIONS
2GP pressurisation units have the following applications:
- Water supply to building service distribution systems
- Generic industrial water supply
- Irrigation for gardens, parks and sports facilities
Versions with two electric pumps:
- 2GP 3M SERIES
- 2GP EVMSG SERIES
Versions with three electric pumps:
- 3GP 3M SERIES
- 3GP EVMSG SERIES
2GPE-3GPE INDUSTRIAL (VERSIONS ON REQUEST)
Industrial pressure GPE with inverter
TYPICAL APPLICATIONS GPE pressurisation units have the following applications:
- Water supply or distribution networks, apartment blocks, schools, hotels, etc.
- Generic industrial water supply
- Irrigation for gardens, parks and sports facilities
Versions with two electric pumps with inverter:
- 2GPE 3M SERIES
- 2GPE EVMSG SERIES
Versions with three electric pumps with inverter:
- 3GPE 3M SERIES
- 3GPE EVMSG SERIES
FFS-FFB
Fire-fighting
FIRE-FIGHTING UNITS IN COMPLIANCE WITH UNI EN 12845
The EBARA FFS-FFB type pressure boosting units are applied in the automatic activation water supplies for the automatic fire fighting units in compliance with European Standard UNI EN 12845.
Functioning principle
As established by the UNI EN 12845 Standard, if the firefighting unit supply pumps intervene, they are started by a pair of pressure switches via an electric control panel supplied with each pump and they must function continuously until stopping, which only occurs with a manual control. The start-up of the supply pumps can cause simultaneous activation of an acoustic and luminous long distance indicator. The small flow rate jockey pump (pilot), intervenes in the case of small system leaks and is started and stopped automatically by its own electric control panel and relative pressure switch calibrated at a pressure value slightly higher than the pressure switch value of the supply pump. Stopping takes place when system pressure is resetd. The acoustic – luminous indicator also signals a missing phase, the voltage, lack of water and any incorrect position of the shut-off valves both in discharge and suction. The electric control panels are equipped with pump running signals.
Standards and regulations
The FFS-FFB firefighting pressure boosting units are designed and built in compliance with the following Regulations and Standards:
- UNI EN 12845 Standard, extinguisher appliances, water supplies for automatic systems
- UNI EN 12845/10779 Standard, extinguisher systems – Hydrant networks
- 2006/42 EEC Machinery Directive
- 2006/95/CE Low Voltage Directive
- 2004/108 Electromagnetic Compatibility Directive
- European Standards:
- EN60204-1;
- IEC EN60439-1;
- EN61000-6-4;
- EN61000-6-2
Conditions for use
The FFS-FFB firefighting pressure boosting units can be used exclusively as envisioned in the UNI EN 12845 LH, OH, HH Standard, in the automatic activation water supplies for the automatic fire fighting units in civil and industrial activities. The water conveyed must not contain solid bodies and fibres in suspension or vegetation and without aggressive and corrosive chemical substances (UNI EN 12845 8.6).
- Minimum temperature of the water conveyed is 0°C, max temperature 40°C (25°C for submersed multistage pumps)
- Environment functioning temperature is 4°÷40°C at a height not exceeding 1000 m a.s.l.
- Max. relative humidity 50% at +40°C
NB: possibly the pumping unit must be installed underhead (UNI EN 12845)
NB: each pump must have its own independent suction pipe (UNI EN 12845).
Versions available
The EBARA fire fighting units are produced in six versions:
- FFS 11/21 3PS: unit made up from 1 or 2 main surface electric pumps, base-joint monobloc and an electric jockey pump;
- FFBE 11/21 ENR: unit made up from 1 or 2 main surface electric pumps, base-joint monobloc and an electric jockey pump;
- FFS 11/21 EVMG: unit made up from 1 or 2 main surface electric pumps, vertical multistage and an electric jockey pump;
- KIT FFS 11/21 S: unit made up from 1 or 2 main submersed electric pumps, vertical multistage and an electric jockey pump;
- FFBD 11/21: unit made up from 1 or 2 main surface pumps, base-joint monobloc and an electric jockey pump;
- FFBD 111: unit made up from 1 pump and 1 main surface electric pumps, base-joint monobloc and an electric jockey pump.
CABINATI
Fire-fighting
KIT FFS
Fire-fighting
APPLICATIONS
The EBARA KIT FFS 11-21S type pressure boosting units are applied in the automatic activation water supplies for the automatic fire fighting units in compliance with European Standard UNI EN 12845
SPECIFICATIONS
As established by the UNI EN 12845 Standard, if the firefighting unit supply pumps intervene, they are started by a pair of pressure switches via an electric control panel supplied with each pump and they must function continuously until stopping, which only occurs with a manual control. The start-up of the supply pumps can cause simultaneous activation of an acoustic and luminous long distance indicator. The small flow rate jockey pump (pilot), intervenes in the case of small system leaks and is started and stopped automatically by its own electric control panel and relative pressure switch calibrated at a pressure value slightly higher than the pressure switch value of the supply pump. Stopping takes place when system pressure is reset. The acoustic – luminous indicator also signals a missing phase, the voltage, lack of water and any incorrect position of the shut-off valves both in discharge and suction. The electric control panels are equipped with pump running signals.
TECHNICAL DETAILS
KIT FFS 11/21 S: unit made up from 1 or 2 main submersed electric pumps, vertical multistage and an electric jockey pump; The KIT FFS firefighting pressure boosting units can be used exclusively as envisioned in the UNI EN 12845 LH, OH, HH Standard, in the automatic activation water supplies for the automatic fire fighting units in civil and industrial activities. The water conveyed must not contain solid bodies and fibers in suspension or vegetation and without aggressive and corrosive chemical substances (UNI EN 12845 8.6).
- Minimum temperature of the water conveyed is 0°C, max temperature 40°C (25°C for submersed multistage pumps)
- Environment functioning temperature is 4°÷40°C at a height not exceeding 1000 m a.s.l.
- Max. relative humidity 50% at +40°C
NB: possibly the pumping unit must be installed under head (UNI EN 12845)
NB: each pump must have its own independent suction pipe (UNI EN 12845).
FFBE BOX 10 – GR.ANTINCENDIO
Fire-fighting
Available only for Italian market
E-SPD
Control systems and panels
E-SPD is an air-cooled inverter, which can be installed directly on the terminal box, designed to control the start and stop of the pump based on the setpoint of the system pressure. It offers high energy savings and reduced noise levels, along with operating costs. It can be used in residential applications as it conforms to Directive EN 61800-3 Category C2.
TECHNICAL FEATURES
- The inverter installation is user friendly with quick set up which ensures a fast and effective start up.
- It can be adapted to all centrifugal pumps, both horizontal and vertical
- The LCD display allows effective management of all system parameters, including a back-up history
- The E-SPD can protect the system against overpressure, over current, voltage fluctuation, dry running and water leak
- The E-SPD comes equipped with 2 digital inputs and 2 relay outputs in addition to pressure transducer input (4-20 mA).
- The E-SPD is also RS485 compliant which enables connection of up to 8 inverters
TECHNICAL DATA
- Main supply: single-phase 230V, three-phase 400V;
- Motor output (pump): three-phase 230V/400V;
- Output current: 11A;
- Frequency: 50-60 Hz (+/- 2%);
- Max ambient temperature: 40°C;
- Insulation class: F;
- Protection degree: IP55
2GPE CVM E-SPD
Domestic pressure GPE with inverter
Booster sets with two vertical multi-stage pumps. Two CVM series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. 2GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 40°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body and motor support
- External casing in AISI 304
- Impeller, stages and diffuser in glass fibre reinforced techno polymer impeller
- Shaft in AISI 416
- Mechanical seal in Ceramic/Carbon/EPDM
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz,Threephase voltage 230/400V ±10% 50Hz
2GPE EVMSG E-SPD
Domestic pressure GPE with inverter
Booster sets with two vertical multi-stage pumps with stainless steel hydraulics with standardised motor. Two EVMSG series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. 2GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 50°C
- Maximum operating pressure: 16 bar,
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Impeller and shaft in AISI 304
- Cast iron motor bracket
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP55 protection degree
- Single-phase 230V±10% voltage three phase 230/400V ±10% (up to 4 kW) three phase 400/690 ±10% (starting from 5.5 kW)
2GP AGA
Domestic pressure GP with control panel
Booster sets with two horizontal single impeller pumps with cast iron hydraulics. Two pumps of AGA series with 2-pole induction motor with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 45°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Shaft in AISI 303
- Glass fibre reinforced technopolymer impeller for AGA 1.00, brass for the rest of the range
- Mechanical seal in Ceramic/Carbon/NBR
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz,Threephase voltage 230/400V ±10% 50Hz
2GPE MATRIX E-SPD
Domestic pressure GPE with inverter
Booster sets with two horizontal multi-stage pumps with stainless steel hydraulics. Two MATRIX series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. 2GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 50°C for 2GP MATRIX, 40°C for 2GPE MATRIX
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Pump body, impeller and shaft in AISI 304
- Mechanical seal in Ceramic/Carbon/EPDM
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz,Threephase voltage 230/400V ±10% 50Hz
2GP CDA
Domestic pressure GP with control panel
Booster sets with two horizontal twin impeller pumps with cast iron hydraulics. Two CDA series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature:
- 40°C for 2GP CDA 1.00,
- 50°C for the rest of the models
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Shaft in AISI 303 for CDA 1.00-1.50-2.00-3.00, in AISI 304 for CDA 4.00 – 5.50
- Glass fibre reinforced technopolymer impeller for CDA 1.00, brass for the rest of the range
- Mechanical seal in Ceramic/Carbon/NBR
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz,Threephase voltage 230/400V ±10% 50Hz
2GP CVM
Domestic pressure GP with control panel
Booster sets with two vertical multi-stage pumps. Two CVM series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 40°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body and motor support
- External casing in AISI 304
- Impeller, stages and diffuser in glass fibre reinforced techno polymer impeller
- Shaft in AISI 416
- Mechanical seal in Ceramic/Carbon/EPDM
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz,Threephase voltage 230/400V ±10% 50Hz
3GPE CVM E-SPD
Domestic pressure GPE with inverter
Booster sets with three vertical multi-stage pumps. Three CVM series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. 3GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 40°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body and motor support
- External casing in AISI 304
- Impeller, stages and diffuser in glass fibre reinforced technopolymer impeller
- Shaft in AISI 416
- Mechanical seal in Ceramic/Carbon/EPDM
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- 230/400V ±10% 50Hz three phase voltage
3GPE EVMSG E-SPD
Domestic pressure GPE with inverter
Booster sets with three vertical multi-stage pumps with stainless steel with standardised motor Three EVMSG series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. 3GPE version fitted with E-SPD inverter and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 50°C
- Maximum operating pressure: 16 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Impeller and shaft in AISI 304
- Cast iron motor bracket
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP55 protection degree
- Three-phase voltage 230/400V ±10% (up to 4 kW) three phase 400/690 ±10% (starting from 5.5 kW)
2GP 2CDX
Domestic pressure GP with control panel
Booster sets with two horizontal twin impeller pumps with stainless steel hydraulics. Two 2CDX series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 50°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.25-0.1 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Pump body, impeller, shaft in AISI 304
- Mechanical seal in Ceramic/Carbon/NBR
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP55 protection degree
- Single-phase voltage 230V ±10% 50Hz,Threephase voltage 230/400V ±10% 50Hz
2GP EVMSG
Domestic pressure GP with control panel
Booster sets with two vertical multi-stage pumps with stainless steel hydraulics with standardised motor. Two EVMSG series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 50°C,
- Maximum operating pressure: 16 bar,
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Impeller and shaft in AISI 304
- Cast iron motor bracket
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP55 protection degree
- Single-phase 230V±10% voltage three phase 230/400V ±10% (up to 4 kW) three phase 400/690 ±10% (starting from 5.5 kW)
2GP COMPACT
Domestic pressure GP with control panel
Booster sets with two horizontal cast iron multi-stage pumps. Two COMPACT series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 40°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Shaft in AISI 416
- Glass fibre reinforced techno polymer impeller
- Mechanical seal in Ceramic/Carbon/NBR
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz, Three-phase voltage 230/400V ±10% 50Hz
2GP MATRIX
Domestic pressure GP with control panel
Booster sets with two horizontal multi-stage pumps with stainless steel hydraulics. Two MATRIX series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 50°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Pump body, impeller and shaft in AISI 304
- Mechanical seal in Ceramic/Carbon/EPDM
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- Single-phase voltage 230V ±10% 50Hz,Threephase voltage 230/400V ±10% 50Hz
3GP CVM
Domestic pressure GP with control panel
Booster sets with three vertical multi-stage pumps. Three CVM series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 40°C
- Maximum operating pressure: 10 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body and motor support
- External casing in AISI 304
- Impeller, stages and diffuser in glass fibre reinforced techno polymer impeller
- Shaft in AISI 416
- Mechanical seal in Ceramic/Carbon/EPDM
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP44 Protection degree
- 230/400V ±10% 50Hz three phase voltage
3GP EVMSG
Domestic pressure GP with control panel
Booster sets with three vertical multi-stage pumps with stainless steel with standardised motor. Three EVMSG series pumps with self-ventilated 2-pole asynchronous motor, IE3 efficiency class for three phase motors starting from 0.75 kW. The system is equipped as standard with a control panel with alternating pump and is designed for the installation of storage tanks (available on request).
FIELD OF APPLICATION
- Maximum liquid temperature: 50°C
- Maximum operating pressure: 16 bar
- Water with maximum presence of solids: 50 ppm (particle size 0.1-0.25 mm or less), no gas or corrosive and aggressive substances
- Maximum chlorine content: 500 ppm
- Altitude not exceeding 1000 m a.s.l.;
- Humidity 50% without condensation
- Ambient protected against atmospheric agents.
For more information refer to our Data Book on the website www.ebaraeurope.com
ELECTRIC PUMP MATERIALS
- Cast iron pump body
- Impeller and shaft in AISI 304
- Cast iron motor bracket
MOTOR TECHNICAL DATA
- IE3 motor starting from 0.75kW
- Self-ventilated 2-pole asynchronous motor
- Class of insulation F
- IP55 protection degree
- Three-phase voltage 230/400V ±10% (up to 4 kW) three phase 400/690 ±10% (starting from 5.5 kW)
SP SERIES
Control systems and panels
CONTROL PANELS WITH INVERTER
Control panels with inverter SP series modulate the operation of electro pumps responding to the pressure transducer control (measured by flow rate or other external signal 4-20 mA passive) adjusting the speed of the electric pumps to maintain constant the system demand.
VERSION
- “FC”: Control panel for one electric pump with inverter
- “EFC”: Control panel for two or more electric pumps, with single inverter but with electric pumps exchange
- “MFC”: Control panel for two or more electricpumps, with one inverter for each individual electric pump
TECHNICAL DATA
- Power supply voltage: 400V ±10%,
- Three phases without aid of the neutral
- Power supply frequency: 50Hz or 60Hz
- Power for every motor: from 0.75 kW and above
- Type of start-up and power supply for all pumps:
- during the start-up phase, the inverter powers the pump with a voltage ramp, the other pumps have direct or star/delta start-up according to the electric power
- during emergency functioning (controlled by pressure switches) all of the pumps function according to the power size at direct or delta/triangle start-up
- Limits of use (environment temperature): from -10°C to +40°C
- Protection rating:
- IP55 up to 3 kW
- IP44 for greater powers
- Conformity to the CE mark, EN 60204-1; Security electrical equipment.
- EN 60439-1; Switchgear and control gear assemblies.
- EMC standards applied:
- CEI EN 61000-6-1; immunity for residential, commercial, and light industrial environments.
- CEI EN 61000-6-2; industrial immunity.
- CEI EN 61000-6-3; emission for residential, commercial and light industrial environments.
- CEI EN 61000-6-4; industrial emission.
- CEI EN 61000-3-2; harmonic current emission <= 16A (use XL.L line inductance to be installed on request, see ref. 8.1, 8.2).
- Emissions: conformity for residential environments.
- Immunity: conformity for industrial environments.
- Minimum output frequency: 30 Hz